JLCTRequest a quoteQuote

Commercial Cooling Tower Selection for HVAC and Chiller Systems

Jinling supplies JLCT cooling towers for HVAC and air-conditioning duty, covering open cross-flow and counter-flow designs and closed circuit towers. Selection begins with cooling load, water flow, entering and leaving water temperatures, and the site noise limit.

Request a quote for this tower

CTI codes listed
JNT, JNC, JFC series
Export
more than 50 countries and regions
Average lead time
about one month
Rooftop tower with X-braced side intake

Commercial Cooling Towers for HVAC and Air-Conditioning Duty

Jinling builds JLCT commercial cooling towers for HVAC and air-conditioning duty, and the selection is made from project data rather than from a catalogue page. It starts with the cooling load, the design flow rate, the entering and leaving water temperatures, the site noise limit and the measurement point for that limit. Send those figures and the tower family, model size and fan arrangement follow from them.

The range covers the JNT cross-flow open tower, the JFT counter-flow open tower, and the JNC and JFC closed circuit towers. The JNT series is listed with CTI certification code C28A-05R08, the JNC series C28B-09R02 and the JFC series C28D-24R00; the JFT counter-flow open cooling tower has passed CTI certification. Send the project data through the inquiry form and the selection is worked from it.

Commercial cooling tower models and specifications

JNT-45280L cross-flow open cooling tower
ParameterValue
Model NO.JNT-45280L
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsAir Conditioning
Circulating Water Flow Rate205m3/H
Length4500mm
Width2800mm
Height3305mm
Fan Diameter2400mm
Motor Power7.5kw
Inlet Pipe Diameter125*2 DN
Outlet Pipe Diameter200 DN
Overflow Pipe Diameter50 DN
Blowdown Pipe Diameter50 DN
Make-up Water Pipe Diameter25 DN
Operating Weight5570kg
JNT-38221H cross-flow open cooling tower
ParameterValue
Model NO.JNT-38221H
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP and Galvanzied Steel Sheet
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsIndustrial and Air Conditioning
ModelJnt-38221h
Inlet Pipe Diameter125*2DN
Circulating Water Flow Rate154(M³/H)
Fan Pipe Diameter1800mm
Outlet Pipe Diameter200DN
Overflow Pipe Diameter50DN
Drain Pipe Diameter50DN
Self-Priming Pipe Diameter25DN
Application RangesHospital, Industrial, Residential Complex
Operating Weight4020kg
JFT-600X2 counter-flow open cooling tower
ParameterValue
Model NO.JFT-600X2
Cooling MethodCounter Flow
Ventilation ModeMechanical Ventilation
MaterialMetal
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsAir Conditioning,Industrial
Water Flow Rate1000m3/H
Motor Power30kw
Fan Diameter4600mm
FrameSteel Gavanzied Sheet
Fan StackOutside
Weight9400kgs
Overflow Pipe Diameter100DN
Drain Pipe Diameter50DN
Self-Filling Pipe Diameter50DN
Water Inlet Diametr450DN
Water Outlet Diameter450DN
Operating Weight23180kg
Application RangesHospital, Residential,Industrial
Motor Protection RatingIP55
JNT-38221L-6 cross-flow open cooling tower
ParameterValue
Model NO.JNT-38221L-6
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeRectangular
Noise LevelLow
Application FieldsAir Conditioning, Industrial
ModelJnt-38221L-6
Water Flow Rate750m3/H
Motor Power4kwx6
Fan Diameter1800mmx6
FrameSteel Gavanzied Sheet
Fan StackOutside
Weight11160kgs
Inlet Pipe Diameter100*12DN
Outlet Pipe Diameter150DN
Overflow Pipe Diameter50DN
Drain Pipe Diameter50DN
Make-up Pipe Diameter25DN
Main ComponentsMotor, Reducer, Fan, PVC Fill
Motor TypesVFD /Pm Motor
JFT-7242L counter-flow open cooling tower
ParameterValue
Model NO.JFT-7242L
Cooling MethodCounter Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsIndustrial
FrameworkGalvanized Steel Sheet or Stainless Steel
LadderH.D.G. or Stainless Steel
RailingH.D.G. or Stainless Steel
Motor SupperH.D.G. or Stainless Steel
Casing and NeckFRP
Fan StackFRP
Basin and Collection PitFRP+Galvanzied Steel Sheet
Fan MatericalAl-Alloy
MotorTefc.Cl.F
FillingPVC or CPVC or PP
Water Flow Rate857m3/H
Fan Diameter4200mm
Motor Power37kw
Inlet Pipe Diameter400DN
Outlet Pipe Diameter400DN
JNT-53281L cross-flow open cooling tower
ParameterValue
Model NO.JNT-53281L
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeRectangular
Noise LevelLow
Application FieldsAir Conditioning,Industrial
Water Flow Rate300m3/H
Motor Power11kw
Fan Diameter2400mm
FrameSteel Gavanzied Sheet
Fan StackOutside
Wet Weight10230kgs
Dry Weight2990kgs
Overflow Pipe Diameter80DN
Drain Pipe Diameter50DN
Make-up Pipe Diameter50DN
Main ComponentsFan, Motor, Reducer, PVC Fill, Steel Frame
Motor TypesVFD Motor, Pm Motor
JNT-51340N cross-flow open cooling tower
ParameterValue
Model NO.JNT-51340N
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP and Galvanzied Steel Sheet
Air Contact FormWet
Air Contact WayOpen
Tower ShapeRectangular
Noise LevelLow
Application FieldsIndustrial and Air Conditioning
Motor Type & Drive SystemAxial-Flow & V-Belt
Motor TypeTotal Enclosed Fan-Cooled/3phase/Pole
FrameGalvanized Steel Sheet or Stainless Steel
Usagefor Refrigerate
Motor Power15kw
Fan Size3000mm
Water BasinGalvanized Steel Sheet+FRP
Water TankGalvanzied Steel Sheet
Dimension5100*3400*4005mm
Inlet Pipe Diameter200*2DN
Overflow Pipe Diameter80DN
Drain Pipe Diameter50DN
Make-up Pipe Diameter50DN

Commercial Cooling Tower Selection for HVAC Systems

An HVAC cooling tower rejects heat from water-cooled chillers or from air-conditioning plant, and the tower family follows the site and the water. Open cross-flow and open counter-flow towers suit large air volumes where water treatment is accessible; closed circuit towers keep the process fluid inside a coil and suit dusty air or water that must stay clean. Jinling supplies the JNT, JFT, JNC and JFC series. Cross-flow and counter-flow airflow differ in footprint and fan arrangement.

For a commercial building the path runs in order: confirm the cooling load and the flow the plant needs, fix the entering and leaving water temperatures, then check approach and range against the design wet-bulb temperature. Footprint, water quality and maintenance access decide which cooling tower family fits.

Air-conditioning cooling towers serve water-cooled air-conditioning plant and chiller systems by rejecting condenser heat; they are not selected from the air-conditioning unit model alone. Jinling towers work in hospitals, public institutions, rail transit, hotels and property, and photovoltaic energy projects. Give the cooling load, water flow, temperatures, site noise limit and measurement point for the units in the building, and send unusual configurations through the inquiry form.

Pairing a Cooling Tower with a Chiller

A cooling tower for a chiller is sized on the heat the condenser must reject. The inputs are chiller capacity, design flow, entering and leaving condenser-water temperatures, the design wet-bulb condition and the limits of the site.

The chiller produces chilled water for the building, and the cooling tower rejects condenser heat to the atmosphere through evaporation. Open towers expose the condenser water to air, which suits sites with treated water and room for maintenance; closed circuit towers keep the process fluid in a coil, which suits dusty air, high contamination risk or water that must stay clean. Send the chiller and tower design data and the choice follows.

For a chiller with cooling tower selection, send chiller capacity, chilled-water and condenser-water temperatures, design flow, wet-bulb conditions, electrical supply, footprint, the acoustic limit and its measurement point. Closed circuit towers are the usual direction for dusty sites or where water quality is sensitive. Submit the combination through the inquiry form. The chiller, condenser-water pump, tower and controls work as a set: the tower rejects condenser heat, the chiller supplies chilled water, and chillers run efficiently when the tower is sized to match them.

Closed Circuit Towers, Tower Parts and Project Support

The JNC and JFC closed circuit towers suit commercial projects where the process water must be kept away from airborne dirt, and the JNT and JFT open towers suit larger air-conditioning loads. PVC fill, drift eliminators and spray nozzles are supplied for replacement and upgrading work on existing towers.

JLCT traces its origins to 1983 in Zhuji, Zhejiang, and Jinling has worked in cooling towers for more than 40 years. Certification includes ISO 9001, ISO 14001 and ISO 45001 certificates, plus a CCTI certificate and a CE certificate. Warranty is 12 months after commissioning or 18 months after shipment, whichever is earlier, except for artificial damage. Payment is by L/C or T/T, and terms are confirmed in the quotation.

How an order runs

Send your requirements
The circulating water flow rate, inlet and outlet water temperatures, design wet-bulb temperature, site and noise conditions, the tower type you have in mind and the quantity.
Tower selection and quotation
Jinling matches a JLCT tower series and model to the duty and replies with a quotation that states the configuration and the order terms.
Lead time
The average lead time is about one month in both peak and off seasons; the lead time for each order is confirmed in the quotation.
Payment
Jinling accepts payment by L/C and T/T; payment terms are confirmed in the quotation.
Warranty
For cooling towers, the warranty runs 12 months after commissioning or 18 months after shipment, whichever comes first, except for artificial damage.

Request a quotation

Send the flow rate, inlet and outlet water temperatures, wet-bulb temperature, site conditions and quantity.

Or write to sales@coolingtowerfactory.com

* Required