Commercial Cooling Tower Selection for HVAC and Chiller Systems
Jinling supplies JLCT cooling towers for HVAC and air-conditioning duty, covering open cross-flow and counter-flow designs and closed circuit towers. Selection begins with cooling load, water flow, entering and leaving water temperatures, and the site noise limit.
Request a quote for this tower
- CTI codes listed
- JNT, JNC, JFC series
- Export
- more than 50 countries and regions
- Average lead time
- about one month

Commercial Cooling Towers for HVAC and Air-Conditioning Duty
Jinling builds JLCT commercial cooling towers for HVAC and air-conditioning duty, and the selection is made from project data rather than from a catalogue page. It starts with the cooling load, the design flow rate, the entering and leaving water temperatures, the site noise limit and the measurement point for that limit. Send those figures and the tower family, model size and fan arrangement follow from them.
The range covers the JNT cross-flow open tower, the JFT counter-flow open tower, and the JNC and JFC closed circuit towers. The JNT series is listed with CTI certification code C28A-05R08, the JNC series C28B-09R02 and the JFC series C28D-24R00; the JFT counter-flow open cooling tower has passed CTI certification. Send the project data through the inquiry form and the selection is worked from it.

Elevated tower with access platform and stairs 
Tall rectangular tower with gold-toned louvers
Commercial cooling tower models and specifications
| Parameter | Value |
|---|---|
| Model NO. | JNT-45280L |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Air Conditioning |
| Circulating Water Flow Rate | 205m3/H |
| Length | 4500mm |
| Width | 2800mm |
| Height | 3305mm |
| Fan Diameter | 2400mm |
| Motor Power | 7.5kw |
| Inlet Pipe Diameter | 125*2 DN |
| Outlet Pipe Diameter | 200 DN |
| Overflow Pipe Diameter | 50 DN |
| Blowdown Pipe Diameter | 50 DN |
| Make-up Water Pipe Diameter | 25 DN |
| Operating Weight | 5570kg |
| Parameter | Value |
|---|---|
| Model NO. | JNT-38221H |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP and Galvanzied Steel Sheet |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Industrial and Air Conditioning |
| Model | Jnt-38221h |
| Inlet Pipe Diameter | 125*2DN |
| Circulating Water Flow Rate | 154(M³/H) |
| Fan Pipe Diameter | 1800mm |
| Outlet Pipe Diameter | 200DN |
| Overflow Pipe Diameter | 50DN |
| Drain Pipe Diameter | 50DN |
| Self-Priming Pipe Diameter | 25DN |
| Application Ranges | Hospital, Industrial, Residential Complex |
| Operating Weight | 4020kg |
| Parameter | Value |
|---|---|
| Model NO. | JFT-600X2 |
| Cooling Method | Counter Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | Metal |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Air Conditioning,Industrial |
| Water Flow Rate | 1000m3/H |
| Motor Power | 30kw |
| Fan Diameter | 4600mm |
| Frame | Steel Gavanzied Sheet |
| Fan Stack | Outside |
| Weight | 9400kgs |
| Overflow Pipe Diameter | 100DN |
| Drain Pipe Diameter | 50DN |
| Self-Filling Pipe Diameter | 50DN |
| Water Inlet Diametr | 450DN |
| Water Outlet Diameter | 450DN |
| Operating Weight | 23180kg |
| Application Ranges | Hospital, Residential,Industrial |
| Motor Protection Rating | IP55 |
| Parameter | Value |
|---|---|
| Model NO. | JNT-38221L-6 |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Rectangular |
| Noise Level | Low |
| Application Fields | Air Conditioning, Industrial |
| Model | Jnt-38221L-6 |
| Water Flow Rate | 750m3/H |
| Motor Power | 4kwx6 |
| Fan Diameter | 1800mmx6 |
| Frame | Steel Gavanzied Sheet |
| Fan Stack | Outside |
| Weight | 11160kgs |
| Inlet Pipe Diameter | 100*12DN |
| Outlet Pipe Diameter | 150DN |
| Overflow Pipe Diameter | 50DN |
| Drain Pipe Diameter | 50DN |
| Make-up Pipe Diameter | 25DN |
| Main Components | Motor, Reducer, Fan, PVC Fill |
| Motor Types | VFD /Pm Motor |
| Parameter | Value |
|---|---|
| Model NO. | JFT-7242L |
| Cooling Method | Counter Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Industrial |
| Framework | Galvanized Steel Sheet or Stainless Steel |
| Ladder | H.D.G. or Stainless Steel |
| Railing | H.D.G. or Stainless Steel |
| Motor Supper | H.D.G. or Stainless Steel |
| Casing and Neck | FRP |
| Fan Stack | FRP |
| Basin and Collection Pit | FRP+Galvanzied Steel Sheet |
| Fan Materical | Al-Alloy |
| Motor | Tefc.Cl.F |
| Filling | PVC or CPVC or PP |
| Water Flow Rate | 857m3/H |
| Fan Diameter | 4200mm |
| Motor Power | 37kw |
| Inlet Pipe Diameter | 400DN |
| Outlet Pipe Diameter | 400DN |
| Parameter | Value |
|---|---|
| Model NO. | JNT-53281L |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Rectangular |
| Noise Level | Low |
| Application Fields | Air Conditioning,Industrial |
| Water Flow Rate | 300m3/H |
| Motor Power | 11kw |
| Fan Diameter | 2400mm |
| Frame | Steel Gavanzied Sheet |
| Fan Stack | Outside |
| Wet Weight | 10230kgs |
| Dry Weight | 2990kgs |
| Overflow Pipe Diameter | 80DN |
| Drain Pipe Diameter | 50DN |
| Make-up Pipe Diameter | 50DN |
| Main Components | Fan, Motor, Reducer, PVC Fill, Steel Frame |
| Motor Types | VFD Motor, Pm Motor |
| Parameter | Value |
|---|---|
| Model NO. | JNT-51340N |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP and Galvanzied Steel Sheet |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Rectangular |
| Noise Level | Low |
| Application Fields | Industrial and Air Conditioning |
| Motor Type & Drive System | Axial-Flow & V-Belt |
| Motor Type | Total Enclosed Fan-Cooled/3phase/Pole |
| Frame | Galvanized Steel Sheet or Stainless Steel |
| Usage | for Refrigerate |
| Motor Power | 15kw |
| Fan Size | 3000mm |
| Water Basin | Galvanized Steel Sheet+FRP |
| Water Tank | Galvanzied Steel Sheet |
| Dimension | 5100*3400*4005mm |
| Inlet Pipe Diameter | 200*2DN |
| Overflow Pipe Diameter | 80DN |
| Drain Pipe Diameter | 50DN |
| Make-up Pipe Diameter | 50DN |
Commercial Cooling Tower Selection for HVAC Systems
An HVAC cooling tower rejects heat from water-cooled chillers or from air-conditioning plant, and the tower family follows the site and the water. Open cross-flow and open counter-flow towers suit large air volumes where water treatment is accessible; closed circuit towers keep the process fluid inside a coil and suit dusty air or water that must stay clean. Jinling supplies the JNT, JFT, JNC and JFC series. Cross-flow and counter-flow airflow differ in footprint and fan arrangement.
For a commercial building the path runs in order: confirm the cooling load and the flow the plant needs, fix the entering and leaving water temperatures, then check approach and range against the design wet-bulb temperature. Footprint, water quality and maintenance access decide which cooling tower family fits.
Air-conditioning cooling towers serve water-cooled air-conditioning plant and chiller systems by rejecting condenser heat; they are not selected from the air-conditioning unit model alone. Jinling towers work in hospitals, public institutions, rail transit, hotels and property, and photovoltaic energy projects. Give the cooling load, water flow, temperatures, site noise limit and measurement point for the units in the building, and send unusual configurations through the inquiry form.
Pairing a Cooling Tower with a Chiller
A cooling tower for a chiller is sized on the heat the condenser must reject. The inputs are chiller capacity, design flow, entering and leaving condenser-water temperatures, the design wet-bulb condition and the limits of the site.
The chiller produces chilled water for the building, and the cooling tower rejects condenser heat to the atmosphere through evaporation. Open towers expose the condenser water to air, which suits sites with treated water and room for maintenance; closed circuit towers keep the process fluid in a coil, which suits dusty air, high contamination risk or water that must stay clean. Send the chiller and tower design data and the choice follows.
For a chiller with cooling tower selection, send chiller capacity, chilled-water and condenser-water temperatures, design flow, wet-bulb conditions, electrical supply, footprint, the acoustic limit and its measurement point. Closed circuit towers are the usual direction for dusty sites or where water quality is sensitive. Submit the combination through the inquiry form. The chiller, condenser-water pump, tower and controls work as a set: the tower rejects condenser heat, the chiller supplies chilled water, and chillers run efficiently when the tower is sized to match them.
Closed Circuit Towers, Tower Parts and Project Support
The JNC and JFC closed circuit towers suit commercial projects where the process water must be kept away from airborne dirt, and the JNT and JFT open towers suit larger air-conditioning loads. PVC fill, drift eliminators and spray nozzles are supplied for replacement and upgrading work on existing towers.
JLCT traces its origins to 1983 in Zhuji, Zhejiang, and Jinling has worked in cooling towers for more than 40 years. Certification includes ISO 9001, ISO 14001 and ISO 45001 certificates, plus a CCTI certificate and a CE certificate. Warranty is 12 months after commissioning or 18 months after shipment, whichever is earlier, except for artificial damage. Payment is by L/C or T/T, and terms are confirmed in the quotation.
How an order runs
- Send your requirements
- The circulating water flow rate, inlet and outlet water temperatures, design wet-bulb temperature, site and noise conditions, the tower type you have in mind and the quantity.
- Tower selection and quotation
- Jinling matches a JLCT tower series and model to the duty and replies with a quotation that states the configuration and the order terms.
- Lead time
- The average lead time is about one month in both peak and off seasons; the lead time for each order is confirmed in the quotation.
- Payment
- Jinling accepts payment by L/C and T/T; payment terms are confirmed in the quotation.
- Warranty
- For cooling towers, the warranty runs 12 months after commissioning or 18 months after shipment, whichever comes first, except for artificial damage.
Request a quotation
Send the flow rate, inlet and outlet water temperatures, wet-bulb temperature, site conditions and quantity.
Or write to sales@coolingtowerfactory.com