FRP Cooling Tower Range for Open Wet Cooling
JLCT builds FRP-cased open cooling towers for HVAC, industrial and process cooling duty. This page covers the open wet range, the materials and structure behind the casing, and the supplier checks that matter before quotation.
Request a quote for this tower
- CTI codes listed
- JNT, JNC, JFC series
- Export
- more than 50 countries and regions
- Average lead time
- about one month

FRP Cooling Tower Range for Open Wet Cooling
JLCT offers an FRP cooling tower range for open wet cooling built around the JNT cross-flow open cooling tower and JFT counter-flow open cooling tower, with the square JNT open tower cards shown as product cards. Each card carries the specification tables on this page. Share flow rate, water temperatures, wet-bulb temperature and site conditions through the enquiry section for selection and quotation.
FRP casing gives the tower a moulded shell that resists weather exposure and protects internal fill, drift eliminators and water distribution. The enquiry section is the starting point for a direct selection or quotation request when project data is ready.

Outdoor tower with broad X-braced side intake 
Clad tower side with casing detail inset
FRP cooling tower models and specifications
| Parameter | Value |
|---|---|
| Model NO. | JNT-72521N |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Industrial |
| Circulating Water Flow Rate | 903m3/H |
| Length | 7200mm |
| Width | 5200mm |
| Height | 5515mm |
| Fan Diameter | 4200mm |
| Motor Power | 37kw |
| Inlet Pipe Diameter | 200*4 DN |
| Outlet Pipe Diameter | 300*2 DN |
| Overflow Pipe Diameter | 100 DN |
| Blowdown Pipe Diameter | 50 DN |
| Make-up Water Dia,Meter | 50 DN |
| Operating Weight | 15510kg |
| Parameter | Value |
|---|---|
| Cooling Method | Cross Flow |
| Model NO. | JNT-800L/M |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Rectangular |
| Noise Level | Low |
| Application Fields | Air Conditioning,Industrial |
| Water Flow Rate | 800m3/H |
| Motor Power | 7.5kw |
| Fan Diameter | 2000mm |
| Frame | Steel Gavanzied Sheet |
| Fan Stack | Outside |
| Wet Weight | 20120kgs |
| Dry Weight | 7520kgs |
| Parameter | Value |
|---|---|
| Cooling Method | Cross Flow |
| Model NO. | JNT-125X10 |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Rectangular |
| Noise Level | Low |
| Application Fields | Industrial and Air Conditioning |
| Motor Type & Drive System | Axial-Flow & V-Belt |
| Motor Type | Total Enclosed Fan-Cooled/3phase/Pole |
| Frame | Galvanized Steel Sheet or Stainless Steel |
| Usage | for Refrigerate |
| Motor Power | 5.5kwx10 |
| Fan Size | 1800mmx10 |
| Weight | 14850kgs |
| Parameter | Value |
|---|---|
| Model NO. | JNT-350 |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Rectangular |
| Noise Level | Low |
| Application Fields | Air Conditioning,Industrial |
| Model | Jnt-350 |
| Water Flow Rate | 350m3/H |
| Motor Power | 15kw |
| Fan Diameter | 2400mm |
| Frame | Steel Gavanzied Sheet |
| Fan Stack | Outside |
| Main Components | Motor, Reducer, Fan, Steel Frame |
| Motor Options | VFD /Pm Motor |
| Applications | Residential,Commercial Areas, Hotle |
| Parameter | Value |
|---|---|
| Model NO. | JNT-45280N |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP and HDG and Others |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Ultra Low |
| Application Fields | Industrial |
| Model | Jnt-45280n |
| Water Flow Rate | 232m3/H |
| Overall Dimensions | 4800X2800X3305mm |
| Fan Diameter | 2400mmx1 |
| Air Volume | 1395m3/Min |
| Fan Type | Axial-Flow |
| Drive System | V-Belt |
| Motor Type | Total Enclosed Fan-Cooled/3phase/Pole |
| Motor Rate Output | 11kwx1 |
| Inlet Pipe Diameter | 150*2DN |
| Outlet Pipe Diameter | 250DN |
| Overflow Pipe Diameter | 50DN |
| Parameter | Value |
|---|---|
| Model NO. | JFT-4834N-2 |
| Cooling Method | Counter Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Air Conditioning,Industrial |
| Model | Jft-4834n-2 |
| Water Flow Rate | 776m3/H |
| Dimension | 4800*4800*3200mm |
| Motor Power | 15kwx2 |
| Fan Diameter | 3400mmx2 |
| Frame | Steel Gavanzied Sheet |
| Fan Stack | Outside |
| Dry Weight | 7640kgs |
| Wet Weight | 18060kgs |
| Inlet Water Pipe Diameter | 300DN |
| Outlet Water Pipe Diameter | 300DN |
| Overflow Pipe Diameter | 80DN |
| Drain Pipe Diameter | 50DN |
| Self-Priming Pipe Diameter | 50DN |
| Parameter | Value |
|---|---|
| Model NO. | JNT-59341L |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Rectangular |
| Noise Level | Low |
| Application Fields | Air Conditioning,Industrial |
| Water Flow Rate | 350m3/H |
| Motor Power | 11kw |
| Fan Diameter | 3000mm |
| Frame | Steel Gavanzied Sheet |
| Fan Stack | Outside |
| Wet Weight | 8450kgs |
| Dry Weight | 3500kgs |
| Water Inlet Pipe Size | 150*4DN |
| Water Outlet Pipe Size | 300DN |
| Overflow Pipe Diameter | 80DN |
| Drain Pipe Diameter | 50DN |
| Make-up Pipe Diameter | 50DN |
| Fill Materials | PVC/CPVC |
| Motor Types | VFD/Pm Motor |
FRP and Fiberglass Cooling Tower Construction
In general industry use, a fiberglass cooling tower and an FRP cooling tower describe the same casing concept: glass fibre reinforcement set in a plastic resin to form moulded panels and shells. Buyers and contractors often use the terms interchangeably. FRP construction is chosen for weather resistance, moulded shapes and a relatively light shell compared with some metal casings.
Within the JLCT range, the JNT cross-flow open cooling tower and the JFT counter-flow open cooling tower cards on this page sit in this fiberglass and FRP construction family. Their parameters remain in the specification tables on this page, so compare casing type against the table data. The crossflow versus counterflow guide explains the airflow choice.
Open Loop and Open Circuit Cooling Towers
An open loop cooling tower, also called an open circuit cooling tower, exposes the circulating water to air inside the tower. Water is distributed over fill, contacts the air stream and returns to the process, while evaporation and drift remove part of the water. Because the water contacts air directly, water quality, drift control and make-up water management matter in operation.
JLCT open loop models in this range are the JNT cross-flow open cooling tower and the JFT counter-flow open cooling tower, shown as product cards with the specification tables on this page. For type choice, use the evaporative cooling guide. A closed circuit tower keeps process water inside a coil or tube bundle and uses a separate spray water circuit; FRP closed circuit options are covered in the closed circuit cooling towers guide.
FRP and Fiberglass Cooling Tower Manufacturers
Zhejiang Jinling Refrigeration Engineering Co., Ltd. sells cooling towers under the JLCT brand and is an FRP cooling tower manufacturer integrating R&D, manufacturing, sales and service. JLCT traces its origins to 1983 in Zhuji City, Zhejiang Province, China, and has developed through more than 40 years of work into a manufacturer of cooling towers and refrigeration equipment.
When comparing fiberglass cooling tower manufacturers for a tower project, compare the series offered, specification table parameters, and the evidence tied to each series. Jinling is listed with CTI certification code C28A-05R08 for the JNT cross-flow open cooling tower, the JFT counter-flow open cooling tower has passed CTI certification, and inspection reports cover the JNT, JFT, JNC and JFC series. ISO 9001, ISO 14001 and ISO 45001 certificates support supplier review. Send flow rate, temperatures, wet-bulb temperature and site conditions through the enquiry form for a quotation; payment terms and lead time are confirmed in the quotation.
FRP Cooling Tower Structure
The FRP cooling tower structure is formed by moulded casing panels and a supporting frame that carries fill, water distribution, drift eliminators and the fan stack. The casing protects internal parts from weather and gives the tower its shape; the frame carries mechanical and water loads. Fill provides wetted surface for heat transfer, drift eliminators reduce water carryover, and spray nozzles distribute hot water over the fill.
The JNT cross-flow open cooling tower and JFT counter-flow open cooling tower cards on this page connect this general structure to actual model data. Use the specification tables on this page for dimensions, fan diameter, motor power, pipe sizes and weights. For maintenance, inspect panel condition, frame fastenings, fill cleanliness, drift eliminator fit and nozzle performance, and plan cleaning access at layout stage. See cooling tower parts for replacement fill and spray nozzles; send model-specific assembly, parts and selection questions through the enquiry form.
Square Cooling Tower Models and Listing Specifications
The square cooling tower range for open cooling covers the JNT cross-flow open cooling towers below, each with its own specification table. The tables give the parameters for each model, including flow rate, dimensions, fan diameter, motor power and connection sizes. CTI certification code C28A-05R08 applies to the JNT series cross-flow open cooling tower.
For cross-flow versus counter-flow choice, use the evaporative cooling guide; the JFT counter-flow open cooling tower cards cover the counter-flow open option where that airflow pattern suits the layout. Share flow rate, temperatures, wet-bulb temperature and site conditions through the enquiry section for a model recommendation and quotation.
How an order runs
- Send your requirements
- The circulating water flow rate, inlet and outlet water temperatures, design wet-bulb temperature, site and noise conditions, the tower type you have in mind and the quantity.
- Tower selection and quotation
- Jinling matches a JLCT tower series and model to the duty and replies with a quotation that states the configuration and the order terms.
- Lead time
- The average lead time is about one month in both peak and off seasons; the lead time for each order is confirmed in the quotation.
- Payment
- Jinling accepts payment by L/C and T/T; payment terms are confirmed in the quotation.
- Warranty
- For cooling towers, the warranty runs 12 months after commissioning or 18 months after shipment, whichever comes first, except for artificial damage.
Request a quotation
Send the flow rate, inlet and outlet water temperatures, wet-bulb temperature, site conditions and quantity.
Or write to sales@coolingtowerfactory.com