JLCTRequest a quoteQuote

FRP Cooling Tower Range for Open Wet Cooling

JLCT builds FRP-cased open cooling towers for HVAC, industrial and process cooling duty. This page covers the open wet range, the materials and structure behind the casing, and the supplier checks that matter before quotation.

Request a quote for this tower

CTI codes listed
JNT, JNC, JFC series
Export
more than 50 countries and regions
Average lead time
about one month
Rectangular tower with slatted side panels

FRP Cooling Tower Range for Open Wet Cooling

JLCT offers an FRP cooling tower range for open wet cooling built around the JNT cross-flow open cooling tower and JFT counter-flow open cooling tower, with the square JNT open tower cards shown as product cards. Each card carries the specification tables on this page. Share flow rate, water temperatures, wet-bulb temperature and site conditions through the enquiry section for selection and quotation.

FRP casing gives the tower a moulded shell that resists weather exposure and protects internal fill, drift eliminators and water distribution. The enquiry section is the starting point for a direct selection or quotation request when project data is ready.

FRP cooling tower models and specifications

JNT-72521N cross-flow open cooling tower
ParameterValue
Model NO.JNT-72521N
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsIndustrial
Circulating Water Flow Rate903m3/H
Length7200mm
Width5200mm
Height5515mm
Fan Diameter4200mm
Motor Power37kw
Inlet Pipe Diameter200*4 DN
Outlet Pipe Diameter300*2 DN
Overflow Pipe Diameter100 DN
Blowdown Pipe Diameter50 DN
Make-up Water Dia,Meter50 DN
Operating Weight15510kg
JNT-800L/M cross-flow open cooling tower
ParameterValue
Cooling MethodCross Flow
Model NO.JNT-800L/M
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeRectangular
Noise LevelLow
Application FieldsAir Conditioning,Industrial
Water Flow Rate800m3/H
Motor Power7.5kw
Fan Diameter2000mm
FrameSteel Gavanzied Sheet
Fan StackOutside
Wet Weight20120kgs
Dry Weight7520kgs
JNT-125X10 cross-flow open cooling tower
ParameterValue
Cooling MethodCross Flow
Model NO.JNT-125X10
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeRectangular
Noise LevelLow
Application FieldsIndustrial and Air Conditioning
Motor Type & Drive SystemAxial-Flow & V-Belt
Motor TypeTotal Enclosed Fan-Cooled/3phase/Pole
FrameGalvanized Steel Sheet or Stainless Steel
Usagefor Refrigerate
Motor Power5.5kwx10
Fan Size1800mmx10
Weight14850kgs
JNT-350 cross-flow open cooling tower
ParameterValue
Model NO.JNT-350
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeRectangular
Noise LevelLow
Application FieldsAir Conditioning,Industrial
ModelJnt-350
Water Flow Rate350m3/H
Motor Power15kw
Fan Diameter2400mm
FrameSteel Gavanzied Sheet
Fan StackOutside
Main ComponentsMotor, Reducer, Fan, Steel Frame
Motor OptionsVFD /Pm Motor
ApplicationsResidential,Commercial Areas, Hotle
JNT-45280N cross-flow open cooling tower
ParameterValue
Model NO.JNT-45280N
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP and HDG and Others
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelUltra Low
Application FieldsIndustrial
ModelJnt-45280n
Water Flow Rate232m3/H
Overall Dimensions4800X2800X3305mm
Fan Diameter2400mmx1
Air Volume1395m3/Min
Fan TypeAxial-Flow
Drive SystemV-Belt
Motor TypeTotal Enclosed Fan-Cooled/3phase/Pole
Motor Rate Output11kwx1
Inlet Pipe Diameter150*2DN
Outlet Pipe Diameter250DN
Overflow Pipe Diameter50DN
JFT-4834N-2 counter-flow open cooling tower
ParameterValue
Model NO.JFT-4834N-2
Cooling MethodCounter Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsAir Conditioning,Industrial
ModelJft-4834n-2
Water Flow Rate776m3/H
Dimension4800*4800*3200mm
Motor Power15kwx2
Fan Diameter3400mmx2
FrameSteel Gavanzied Sheet
Fan StackOutside
Dry Weight7640kgs
Wet Weight18060kgs
Inlet Water Pipe Diameter300DN
Outlet Water Pipe Diameter300DN
Overflow Pipe Diameter80DN
Drain Pipe Diameter50DN
Self-Priming Pipe Diameter50DN
JNT-59341L cross-flow open cooling tower
ParameterValue
Model NO.JNT-59341L
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeRectangular
Noise LevelLow
Application FieldsAir Conditioning,Industrial
Water Flow Rate350m3/H
Motor Power11kw
Fan Diameter3000mm
FrameSteel Gavanzied Sheet
Fan StackOutside
Wet Weight8450kgs
Dry Weight3500kgs
Water Inlet Pipe Size150*4DN
Water Outlet Pipe Size300DN
Overflow Pipe Diameter80DN
Drain Pipe Diameter50DN
Make-up Pipe Diameter50DN
Fill MaterialsPVC/CPVC
Motor TypesVFD/Pm Motor

FRP and Fiberglass Cooling Tower Construction

In general industry use, a fiberglass cooling tower and an FRP cooling tower describe the same casing concept: glass fibre reinforcement set in a plastic resin to form moulded panels and shells. Buyers and contractors often use the terms interchangeably. FRP construction is chosen for weather resistance, moulded shapes and a relatively light shell compared with some metal casings.

Within the JLCT range, the JNT cross-flow open cooling tower and the JFT counter-flow open cooling tower cards on this page sit in this fiberglass and FRP construction family. Their parameters remain in the specification tables on this page, so compare casing type against the table data. The crossflow versus counterflow guide explains the airflow choice.

Open Loop and Open Circuit Cooling Towers

An open loop cooling tower, also called an open circuit cooling tower, exposes the circulating water to air inside the tower. Water is distributed over fill, contacts the air stream and returns to the process, while evaporation and drift remove part of the water. Because the water contacts air directly, water quality, drift control and make-up water management matter in operation.

JLCT open loop models in this range are the JNT cross-flow open cooling tower and the JFT counter-flow open cooling tower, shown as product cards with the specification tables on this page. For type choice, use the evaporative cooling guide. A closed circuit tower keeps process water inside a coil or tube bundle and uses a separate spray water circuit; FRP closed circuit options are covered in the closed circuit cooling towers guide.

FRP and Fiberglass Cooling Tower Manufacturers

Zhejiang Jinling Refrigeration Engineering Co., Ltd. sells cooling towers under the JLCT brand and is an FRP cooling tower manufacturer integrating R&D, manufacturing, sales and service. JLCT traces its origins to 1983 in Zhuji City, Zhejiang Province, China, and has developed through more than 40 years of work into a manufacturer of cooling towers and refrigeration equipment.

When comparing fiberglass cooling tower manufacturers for a tower project, compare the series offered, specification table parameters, and the evidence tied to each series. Jinling is listed with CTI certification code C28A-05R08 for the JNT cross-flow open cooling tower, the JFT counter-flow open cooling tower has passed CTI certification, and inspection reports cover the JNT, JFT, JNC and JFC series. ISO 9001, ISO 14001 and ISO 45001 certificates support supplier review. Send flow rate, temperatures, wet-bulb temperature and site conditions through the enquiry form for a quotation; payment terms and lead time are confirmed in the quotation.

FRP Cooling Tower Structure

The FRP cooling tower structure is formed by moulded casing panels and a supporting frame that carries fill, water distribution, drift eliminators and the fan stack. The casing protects internal parts from weather and gives the tower its shape; the frame carries mechanical and water loads. Fill provides wetted surface for heat transfer, drift eliminators reduce water carryover, and spray nozzles distribute hot water over the fill.

The JNT cross-flow open cooling tower and JFT counter-flow open cooling tower cards on this page connect this general structure to actual model data. Use the specification tables on this page for dimensions, fan diameter, motor power, pipe sizes and weights. For maintenance, inspect panel condition, frame fastenings, fill cleanliness, drift eliminator fit and nozzle performance, and plan cleaning access at layout stage. See cooling tower parts for replacement fill and spray nozzles; send model-specific assembly, parts and selection questions through the enquiry form.

Square Cooling Tower Models and Listing Specifications

The square cooling tower range for open cooling covers the JNT cross-flow open cooling towers below, each with its own specification table. The tables give the parameters for each model, including flow rate, dimensions, fan diameter, motor power and connection sizes. CTI certification code C28A-05R08 applies to the JNT series cross-flow open cooling tower.

For cross-flow versus counter-flow choice, use the evaporative cooling guide; the JFT counter-flow open cooling tower cards cover the counter-flow open option where that airflow pattern suits the layout. Share flow rate, temperatures, wet-bulb temperature and site conditions through the enquiry section for a model recommendation and quotation.

How an order runs

Send your requirements
The circulating water flow rate, inlet and outlet water temperatures, design wet-bulb temperature, site and noise conditions, the tower type you have in mind and the quantity.
Tower selection and quotation
Jinling matches a JLCT tower series and model to the duty and replies with a quotation that states the configuration and the order terms.
Lead time
The average lead time is about one month in both peak and off seasons; the lead time for each order is confirmed in the quotation.
Payment
Jinling accepts payment by L/C and T/T; payment terms are confirmed in the quotation.
Warranty
For cooling towers, the warranty runs 12 months after commissioning or 18 months after shipment, whichever comes first, except for artificial damage.

Request a quotation

Send the flow rate, inlet and outlet water temperatures, wet-bulb temperature, site conditions and quantity.

Or write to sales@coolingtowerfactory.com

* Required