Industrial Cooling Towers for Process and Power Plant Cooling

JLCT manufactures industrial cooling towers for process water, power generation and plant utilities, covering open, closed circuit and large industrial series with engineering, manufacturing and service from Zhuji, Zhejiang.

Request a quote for this tower

CTI codes listed
JNT, JNC, JFC series
Export
more than 50 countries and regions
Average lead time
about one month
Three fan cowls and coil detail insets

Industrial Cooling Tower Selection for Process and Plant Duties

An industrial cooling tower rejects waste heat from process water to the atmosphere, generally by evaporation, in factories, process plants and utility systems. JLCT traces its origins to Zhuji City in 1983 and manufactures cooling towers and refrigeration equipment, including the JBN large industrial tower alongside open and closed circuit series. Send the specific duty—flow rate, water temperatures, wet-bulb temperature and site conditions—through the inquiry form.

Industrial service usually means continuous process loads, higher water temperatures and larger multi-cell arrangements than comfort cooling. Crossflow towers pass air horizontally through the falling water; counterflow towers pass air upward against the water. Open towers cool process water in direct contact with air, while closed circuit towers keep the fluid inside coils. Jinling’s JNT and JFT open towers and JNC and JFC closed circuit towers cover these arrangements; see the crossflow versus counterflow guide.

Industrial cooling tower models and specifications

JFT-5836L counter-flow open cooling tower
ParameterValue
Model NO.JFT-5836L
Cooling MethodCounter Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsAir Conditioning
Circulating Water Flow Rate500m3/H
Length5800mm
Width5800mm
Height5220mm
Fan Diameter3650mm
Motor Power15kw
Inlet Pipe Diameter300DN
Outlet Pipe Diameter300DN
Overflow Pipe Diameter100DN
Drain Pipe Diameter50DN
Self-Compensation Pipe Diameter50DN
Operating Weight12890kg
JNT-45280S cross-flow open multi-cell cooling tower
ParameterValue
Model NO.JNT-45280S
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP and HDG and Others
Air Contact FormWet
Air Contact WayOpen
Tower ShapeRectangular
Noise LevelLow
Application FieldsIndustrial and Air Conditioning
ModelJnt-45280s
Water Flow Rate350m3/H
Tower Body Height2800mm
Fan Diameter2400mm
Fan TypeAxial-Flow
Motor TypeTotal Enclosed Fan-Cooled/3phase/Pole
Motor Rate Output15kw*6
Inlet Pipe Diameter125*2DN
Outlet Pipe Diameter200DN
Overflow Pipe Diameter50DN
Drain Pipe Diameter50DN
Make-up Pipe Diameter25DN
JNT-40261U cross-flow open cooling tower
ParameterValue
Model NO.JNT-40261U
Ventilation ModeMechanical Ventilation
MaterialFRP and Galvanzied Steel Sheet
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsNew Energy, Data Center Industrial
ModelJnt-40261u
Circulating Water Flow Rate142m³/H
Size4000*2600*3905mm
Fan Diameter2000mm
Motor Power3kw
Inlet Pipe Diameter125*2DN
Outlet Pipe Diameter200DN
Overflow Pipe Diameter50DN
Drain Pipe Diameter50DN
Self-Priming Pipe Diameter25DN
Operating Weight4940kg
Main ComponentsCasing, Fan, Motor, Reducer
JNC-5630U cross-flow closed circuit cooling tower
ParameterValue
Model NO.JNC-5630U
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP and Galvanzied Steel Sheet
Air Contact FormWet
Air Contact WayClosed
Tower ShapeSquare
Noise LevelLow
Application FieldsIndustrial and Air Conditioning
ModelJnc-5630u
Circulating Water Flow175 M³/H
Fan Diameter2800mm
Power11kw
Pump Power4*2kw
Inlet Water Pipe Diameter150*2DN
Outlet Water Pipe Diameter150*2DN
Operating Weight14800kg
Motor TypesPF/VFD Motor
Drive TypesBelt/Gear/Direct Drives
Material of Tower FrameCustomized
Main ComponentsPVC Fill, Motor, Pumps, Reducer, Fan
JFT-2520N counter-flow open multi-cell cooling tower
ParameterValue
Model NO.JFT-2520N
Cooling MethodCounter Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsIndustrial
FrameworkGalvanized Steel Sheet or Stainless Steel
LadderGalvanized Steel Sheet or Stainless Steel
RailingGalvanized Steel Sheet or Stainless Steel
Casing and NeckFRP or Galvanized Steel Sheet
Fan StackFRP or Galvanized Steel Sheet
Basin and Collection PitFRP +Galvanized Steel Sheet
Fan MatericalAl-Alloy
MotorTefc.Cl.F
FillingPVC or CPVC or PP
BeltComposie Materical
Fan Diameter2000mmx5
Motor Power11kwx5
Tower Size2560*2560*4110mm
Inlet Pipe Diameter150DN
JFT-2520S counter-flow open cooling tower
ParameterValue
Model NO.JFT-2520S
Cooling MethodCounter Flow
Ventilation ModeMechanical Ventilation
MaterialFRP
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsAir Conditioning
Circulating Water Flow Rate90m3/H
Length2560mm
Width2560mm
Height4110mm
Fan Diameter2000mm
Motor Power22kw
Inlet Pipe Diameter150DN
Outlet Pipe Diameter150DN
Overflow Pipe Diameter50DN
Drain Pipe Diameter50DN
Self-Compensation Pipe Diameter25DN
Operating Weight2870kg
JNT-79521H cross-flow open cooling tower
ParameterValue
Model NO.JNT-79521H
Cooling MethodCross Flow
Ventilation ModeMechanical Ventilation
MaterialFRP and Galvanzied Steel Sheet
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsIndustrial and Air Conditioning
ModelJnt-79521h
Inlet Pipe Diameter200*4DN
Circulating Water Flow Rate1000(M³/H)
Fan Diameter4400mm
Outlet Pipe Diameter300*2DN
Overflow Pipe Diameter100DN
Drain Pipe Diameter50DN
Self-Priming Pipe Diameter50DN
Application RangesHospital, Industrial, Residential Complex
Operating Weight17310kg
JFT-250L-3 counter-flow open cooling tower
ParameterValue
Model NO.JFT-250L-3
Cooling MethodCounter Flow
Ventilation ModeMechanical Ventilation
MaterialMetal
Air Contact FormWet
Air Contact WayOpen
Tower ShapeSquare
Noise LevelLow
Application FieldsAir Conditioning,Industrial
Water Flow Rate750m3/H
Size12600X4200X4920mm
Motor Power7.5kwx3
Fan Diameter2400mm
FrameSteel Gavanzied Sheet
Fan StackOutside
Dry Weight6720kgs
Running Weight17790kgs
MaterialsFRP, DIP-Hot Galvanized Steel
Main ComponentsMotor, Steel Frame, Fan, Reducer
All Product SeriesJnt,Jft,Jfc,Jnc

Cooling Towers for Power Plants and Power Stations

In a power plant, the cooling tower rejects heat picked up by condenser cooling water so the steam cycle can repeat. Tower choice affects water use and visible plume, so the cooling water source and site conditions belong in the selection brief.

For a power plant project, specify an open tower where circulating condenser water can be cooled in direct contact with air. Choose a closed circuit tower where the fluid must stay inside coils, such as when contamination is not permitted. Multi-cell layouts allow staged operation as load changes. Jinling’s range includes power-plant-oriented units such as a galvanized steel counter-flow tower in the JFT series; send duty conditions through the inquiry form.

A thermal power plant integrates the tower into the cooling water loop: condenser water circulates to the tower, is distributed over the fill, meets an air stream and returns cooled. Makeup water replaces evaporation and drift. Range and approach, water quality and available space are selection factors. JLCT’s open towers, closed circuit towers, JBN large industrial tower and multi-cell arrangements let several duties be sourced from the same manufacturer; remaining questions go to the inquiry form.

Open and Closed Circuit Industrial Water Cooling Towers

An industrial water cooling tower is selected around water quality, temperature and contamination risk. In an open circuit tower, process water is cooled in direct contact with air as it passes over the fill; this suits many process and HVAC duties where the water can be exposed. In a closed circuit tower, the fluid stays inside coils and is cooled by sprayed water, which suits dusty sites or systems where contamination is not permitted.

Jinling’s JNT cross-flow and JFT counter-flow open towers serve open circuit duties, while the JNC and JFC closed circuit towers serve closed circuit duties. The JNC tower is listed with CTI certification code C28B-09R02 and the JFC tower carries C28D-24R00; the JNT cross-flow open tower is listed with C28A-05R08. Selection depends on your water data; send the analysis, flow rate, temperatures, wet-bulb temperature and space through the inquiry form, and read the closed circuit guide.

Modular Cooling Tower Design and Multi-Cell Layouts

A modular cooling tower is built as cells that are combined on site rather than as a large unit. This lets capacity be added in steps, keeps factory work repeatable and allows maintenance to be staged cell by cell while other cells continue in service. Multi-cell layouts also support staged operation as load changes, which is useful for process and plant cooling duties.

For a modular arrangement, confirm footprint, piping headers, basin layout and access for each cell before selection. A large unit can be simpler where space and load are fixed; a modular layout suits duties that will grow or where maintenance must avoid a full shutdown. Jinling’s JNC and JFC closed circuit towers and JNT and JFT open towers cover these duties; send the duty through the inquiry form.

Stainless Steel Cooling Tower Construction

A stainless steel cooling tower is specified where corrosion risk from water chemistry or site atmosphere is high. Stainless steel resists attack better than mild steel in many aggressive conditions, but the grade and thickness must match the water and the welded details. It is not a substitute for water treatment; it changes the material choice, not the need to control scaling, fouling and biological growth.

One JFT counter-flow open tower model offers FRP, galvanized steel or stainless steel. Closed circuit towers keep the process fluid inside coils, so coil and casing materials can be reviewed against the water and surrounding air. Material selection is confirmed with the quotation. Share water analysis, chloride level, site atmosphere and cleaning method through the inquiry form.

How an order runs

Send your requirements
The circulating water flow rate, inlet and outlet water temperatures, design wet-bulb temperature, site and noise conditions, the tower type you have in mind and the quantity.
Tower selection and quotation
Jinling matches a JLCT tower series and model to the duty and replies with a quotation that states the configuration and the order terms.
Lead time
The average lead time is about one month in both peak and off seasons; the lead time for each order is confirmed in the quotation.
Payment
Jinling accepts payment by L/C and T/T; payment terms are confirmed in the quotation.
Warranty
For cooling towers, the warranty runs 12 months after commissioning or 18 months after shipment, whichever comes first, except for artificial damage.

Request a quotation

Send the flow rate, inlet and outlet water temperatures, wet-bulb temperature, site conditions and quantity.