Industrial Cooling Towers for Process and Power Plant Cooling
JLCT manufactures industrial cooling towers for process water, power generation and plant utilities, covering open, closed circuit and large industrial series with engineering, manufacturing and service from Zhuji, Zhejiang.
Request a quote for this tower
- CTI codes listed
- JNT, JNC, JFC series
- Export
- more than 50 countries and regions
- Average lead time
- about one month

Industrial Cooling Tower Selection for Process and Plant Duties
An industrial cooling tower rejects waste heat from process water to the atmosphere, generally by evaporation, in factories, process plants and utility systems. JLCT traces its origins to Zhuji City in 1983 and manufactures cooling towers and refrigeration equipment, including the JBN large industrial tower alongside open and closed circuit series. Send the specific duty—flow rate, water temperatures, wet-bulb temperature and site conditions—through the inquiry form.
Industrial service usually means continuous process loads, higher water temperatures and larger multi-cell arrangements than comfort cooling. Crossflow towers pass air horizontally through the falling water; counterflow towers pass air upward against the water. Open towers cool process water in direct contact with air, while closed circuit towers keep the fluid inside coils. Jinling’s JNT and JFT open towers and JNC and JFC closed circuit towers cover these arrangements; see the crossflow versus counterflow guide.

Row of tower cells on steel supports 
Rooftop row of cells beside red piping
Industrial cooling tower models and specifications
| Parameter | Value |
|---|---|
| Model NO. | JFT-5836L |
| Cooling Method | Counter Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Air Conditioning |
| Circulating Water Flow Rate | 500m3/H |
| Length | 5800mm |
| Width | 5800mm |
| Height | 5220mm |
| Fan Diameter | 3650mm |
| Motor Power | 15kw |
| Inlet Pipe Diameter | 300DN |
| Outlet Pipe Diameter | 300DN |
| Overflow Pipe Diameter | 100DN |
| Drain Pipe Diameter | 50DN |
| Self-Compensation Pipe Diameter | 50DN |
| Operating Weight | 12890kg |
| Parameter | Value |
|---|---|
| Model NO. | JNT-45280S |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP and HDG and Others |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Rectangular |
| Noise Level | Low |
| Application Fields | Industrial and Air Conditioning |
| Model | Jnt-45280s |
| Water Flow Rate | 350m3/H |
| Tower Body Height | 2800mm |
| Fan Diameter | 2400mm |
| Fan Type | Axial-Flow |
| Motor Type | Total Enclosed Fan-Cooled/3phase/Pole |
| Motor Rate Output | 15kw*6 |
| Inlet Pipe Diameter | 125*2DN |
| Outlet Pipe Diameter | 200DN |
| Overflow Pipe Diameter | 50DN |
| Drain Pipe Diameter | 50DN |
| Make-up Pipe Diameter | 25DN |
| Parameter | Value |
|---|---|
| Model NO. | JNT-40261U |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP and Galvanzied Steel Sheet |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | New Energy, Data Center Industrial |
| Model | Jnt-40261u |
| Circulating Water Flow Rate | 142m³/H |
| Size | 4000*2600*3905mm |
| Fan Diameter | 2000mm |
| Motor Power | 3kw |
| Inlet Pipe Diameter | 125*2DN |
| Outlet Pipe Diameter | 200DN |
| Overflow Pipe Diameter | 50DN |
| Drain Pipe Diameter | 50DN |
| Self-Priming Pipe Diameter | 25DN |
| Operating Weight | 4940kg |
| Main Components | Casing, Fan, Motor, Reducer |
| Parameter | Value |
|---|---|
| Model NO. | JNC-5630U |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP and Galvanzied Steel Sheet |
| Air Contact Form | Wet |
| Air Contact Way | Closed |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Industrial and Air Conditioning |
| Model | Jnc-5630u |
| Circulating Water Flow | 175 M³/H |
| Fan Diameter | 2800mm |
| Power | 11kw |
| Pump Power | 4*2kw |
| Inlet Water Pipe Diameter | 150*2DN |
| Outlet Water Pipe Diameter | 150*2DN |
| Operating Weight | 14800kg |
| Motor Types | PF/VFD Motor |
| Drive Types | Belt/Gear/Direct Drives |
| Material of Tower Frame | Customized |
| Main Components | PVC Fill, Motor, Pumps, Reducer, Fan |
| Parameter | Value |
|---|---|
| Model NO. | JFT-2520N |
| Cooling Method | Counter Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Industrial |
| Framework | Galvanized Steel Sheet or Stainless Steel |
| Ladder | Galvanized Steel Sheet or Stainless Steel |
| Railing | Galvanized Steel Sheet or Stainless Steel |
| Casing and Neck | FRP or Galvanized Steel Sheet |
| Fan Stack | FRP or Galvanized Steel Sheet |
| Basin and Collection Pit | FRP +Galvanized Steel Sheet |
| Fan Materical | Al-Alloy |
| Motor | Tefc.Cl.F |
| Filling | PVC or CPVC or PP |
| Belt | Composie Materical |
| Fan Diameter | 2000mmx5 |
| Motor Power | 11kwx5 |
| Tower Size | 2560*2560*4110mm |
| Inlet Pipe Diameter | 150DN |
| Parameter | Value |
|---|---|
| Model NO. | JFT-2520S |
| Cooling Method | Counter Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Air Conditioning |
| Circulating Water Flow Rate | 90m3/H |
| Length | 2560mm |
| Width | 2560mm |
| Height | 4110mm |
| Fan Diameter | 2000mm |
| Motor Power | 22kw |
| Inlet Pipe Diameter | 150DN |
| Outlet Pipe Diameter | 150DN |
| Overflow Pipe Diameter | 50DN |
| Drain Pipe Diameter | 50DN |
| Self-Compensation Pipe Diameter | 25DN |
| Operating Weight | 2870kg |
| Parameter | Value |
|---|---|
| Model NO. | JNT-79521H |
| Cooling Method | Cross Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | FRP and Galvanzied Steel Sheet |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Industrial and Air Conditioning |
| Model | Jnt-79521h |
| Inlet Pipe Diameter | 200*4DN |
| Circulating Water Flow Rate | 1000(M³/H) |
| Fan Diameter | 4400mm |
| Outlet Pipe Diameter | 300*2DN |
| Overflow Pipe Diameter | 100DN |
| Drain Pipe Diameter | 50DN |
| Self-Priming Pipe Diameter | 50DN |
| Application Ranges | Hospital, Industrial, Residential Complex |
| Operating Weight | 17310kg |
| Parameter | Value |
|---|---|
| Model NO. | JFT-250L-3 |
| Cooling Method | Counter Flow |
| Ventilation Mode | Mechanical Ventilation |
| Material | Metal |
| Air Contact Form | Wet |
| Air Contact Way | Open |
| Tower Shape | Square |
| Noise Level | Low |
| Application Fields | Air Conditioning,Industrial |
| Water Flow Rate | 750m3/H |
| Size | 12600X4200X4920mm |
| Motor Power | 7.5kwx3 |
| Fan Diameter | 2400mm |
| Frame | Steel Gavanzied Sheet |
| Fan Stack | Outside |
| Dry Weight | 6720kgs |
| Running Weight | 17790kgs |
| Materials | FRP, DIP-Hot Galvanized Steel |
| Main Components | Motor, Steel Frame, Fan, Reducer |
| All Product Series | Jnt,Jft,Jfc,Jnc |
Cooling Towers for Power Plants and Power Stations
In a power plant, the cooling tower rejects heat picked up by condenser cooling water so the steam cycle can repeat. Tower choice affects water use and visible plume, so the cooling water source and site conditions belong in the selection brief.
For a power plant project, specify an open tower where circulating condenser water can be cooled in direct contact with air. Choose a closed circuit tower where the fluid must stay inside coils, such as when contamination is not permitted. Multi-cell layouts allow staged operation as load changes. Jinling’s range includes power-plant-oriented units such as a galvanized steel counter-flow tower in the JFT series; send duty conditions through the inquiry form.
A thermal power plant integrates the tower into the cooling water loop: condenser water circulates to the tower, is distributed over the fill, meets an air stream and returns cooled. Makeup water replaces evaporation and drift. Range and approach, water quality and available space are selection factors. JLCT’s open towers, closed circuit towers, JBN large industrial tower and multi-cell arrangements let several duties be sourced from the same manufacturer; remaining questions go to the inquiry form.
Open and Closed Circuit Industrial Water Cooling Towers
An industrial water cooling tower is selected around water quality, temperature and contamination risk. In an open circuit tower, process water is cooled in direct contact with air as it passes over the fill; this suits many process and HVAC duties where the water can be exposed. In a closed circuit tower, the fluid stays inside coils and is cooled by sprayed water, which suits dusty sites or systems where contamination is not permitted.
Jinling’s JNT cross-flow and JFT counter-flow open towers serve open circuit duties, while the JNC and JFC closed circuit towers serve closed circuit duties. The JNC tower is listed with CTI certification code C28B-09R02 and the JFC tower carries C28D-24R00; the JNT cross-flow open tower is listed with C28A-05R08. Selection depends on your water data; send the analysis, flow rate, temperatures, wet-bulb temperature and space through the inquiry form, and read the closed circuit guide.
Modular Cooling Tower Design and Multi-Cell Layouts
A modular cooling tower is built as cells that are combined on site rather than as a large unit. This lets capacity be added in steps, keeps factory work repeatable and allows maintenance to be staged cell by cell while other cells continue in service. Multi-cell layouts also support staged operation as load changes, which is useful for process and plant cooling duties.
For a modular arrangement, confirm footprint, piping headers, basin layout and access for each cell before selection. A large unit can be simpler where space and load are fixed; a modular layout suits duties that will grow or where maintenance must avoid a full shutdown. Jinling’s JNC and JFC closed circuit towers and JNT and JFT open towers cover these duties; send the duty through the inquiry form.
Stainless Steel Cooling Tower Construction
A stainless steel cooling tower is specified where corrosion risk from water chemistry or site atmosphere is high. Stainless steel resists attack better than mild steel in many aggressive conditions, but the grade and thickness must match the water and the welded details. It is not a substitute for water treatment; it changes the material choice, not the need to control scaling, fouling and biological growth.
One JFT counter-flow open tower model offers FRP, galvanized steel or stainless steel. Closed circuit towers keep the process fluid inside coils, so coil and casing materials can be reviewed against the water and surrounding air. Material selection is confirmed with the quotation. Share water analysis, chloride level, site atmosphere and cleaning method through the inquiry form.
How an order runs
- Send your requirements
- The circulating water flow rate, inlet and outlet water temperatures, design wet-bulb temperature, site and noise conditions, the tower type you have in mind and the quantity.
- Tower selection and quotation
- Jinling matches a JLCT tower series and model to the duty and replies with a quotation that states the configuration and the order terms.
- Lead time
- The average lead time is about one month in both peak and off seasons; the lead time for each order is confirmed in the quotation.
- Payment
- Jinling accepts payment by L/C and T/T; payment terms are confirmed in the quotation.
- Warranty
- For cooling towers, the warranty runs 12 months after commissioning or 18 months after shipment, whichever comes first, except for artificial damage.
Request a quotation
Send the flow rate, inlet and outlet water temperatures, wet-bulb temperature, site conditions and quantity.
Or write to sales@coolingtowerfactory.com